go!
You selected Heating and Cooling Energy Meters:

Local regulations can restrict the use of some products in some countries.
Please get in touch with your local Sensus contact to check which product can fulfil your needs and requirements.

 
 
PolluStat E
Diameter range
15-100
Qn
0, 6-60
Metrological Class
Metrological Class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
2-180 1
Any position
Ultrasonic
Main Power Supply
Battery
AMR
Pulse
Nominal pressure PN
16, 25
Temperature sensor type PT
100.500
 
PolluFlow
Diameter range
15-100
Qn
0, 6-60
Metrological Class
Metrological Class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
5-130
Any position
Ultrasonic
Main Power Supply
Battery
AMR
Pulse
Nominal pressure PN
16, 25 spacer
 
 
PolluTherm DN 20-40
Diameter range
20-40
Qn
1, 5-10
Metrological class
Metrological class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
1-1801
Horizontal & Vertical
*
Velocity
Main Power Supply
Battery
AMR
Pulse
Mechanical
Nominal pressure PN
16, 25
Temperature sensor type PT
100.500
* must order specific version
 
PolluTherm DN 50-300
Diameter range
50-300
Qn
15-600
Metrological class
Metrological class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
1-1802
Any position
*
Mechanical
*
Main Power Supply
Battery
AMR
Pulse
Nominal pressure PN
16-40
Temperature sensor type PT
100.500
* WP WS
 
 
PolluCom C
Diameter range
15-20
Qn
0,6-2,5
Temperature Range - Cold ēC
Temperature Range - Hot ēC
5-1503
Any position
Velocity
Battery
AMR
Pulse
Nominal pressure PN
16 spacer
Temperature sensor type PT
500 spacer
 
PolluCom E
Diameter range
15-20
Qn
0,6-2,5
Metrological class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
5-1503
Any position
Velocity
Battery
AMR
Pulse
Mechanical
Nominal pressure PN
16 spacer
Temperature sensor type PT
500 spacer
 
 
PolluCom M
Diameter range
25-40
Qn
3, 5-10
Metrological class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
5-1304
Horizontal & Vertical
*
Velocity
Battery
AMR
Pulse
Mechanical
Nominal pressure PN
16 spacer
Temperature sensor type PT
500 spacer
* must order specific version
 
PolluWatt Duo DN 20-40
Diameter range
20-40
Qn
1, 5-10
Metrological class
Metrological class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
0-2002
Horizontal & Vertical
*
Velocity
Main Power Supply
AMR
Pulse
Mechanical
Nominal pressure PN
16, 25
Temperature sensor type PT
100.500
* must order specific version
 
 
PolluWatt Duo DN 50-300
Diameter range
50-300
Qn
15-600
Metrological class
Metrological class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
0-2002
Any position
*
Mechanical
Main Power Supply
AMR
Pulse
Nominal pressure PN
16-40
Temperature sensor type PT
100.500
* WP WS
 
SensusBase H
Radio (ISM)
spacer
Temperature Range - Hot ēC
spacer
Battery
spacer
AMR
spacer
 
 
Flow Sensor E-T DNH
Diameter range
15 spacer
Qn
0,6-1,5 spacer
Metrological class
Temperature Range - Cold ēC
10-90
Any position
Velocity
Pulse
Mechanical
Nominal pressure PN
10 spacer
 
Flow Sensor AN 130
Diameter range
20-40
Qn
1, 5-10
Metrological class
Temperature Range - Cold ēC
Temperature Range - Hot ēC
10-130
Horizontal & Vertical
*
Mechanical
Velocity
Pulse
Nominal pressure PN
16, 25 spacer
* must order specific version
 
 
WS-Dynamic 130° C
Diameter range
50-150
Qn
15-150
Temperature Range - Hot ēC
spacer
Metrological class
spacer
Horizontal
spacer
Mechanical
spacer
Pulse
spacer
Nominal pressure PN
16, 40 spacer
 
WP-Dynamic 130° C
Diameter range
40-300
Qn
10-600
Temperature Range - Hot ēC
spacer
Metrological class
spacer
Any position
spacer
Mechanical
spacer
Pulse
spacer
Nominal pressure PN
16 spacer
* DN50-150
 
 
WP QF PN25 / 40
Diameter range
50-300
Qn
15-600
Metrological class
spacer
Temperature Range - Hot ēC
spacer
Any position
spacer
Mechanical
spacer
Pulse
spacer
Nominal pressure PN
40 (25) spacer
 
WS PE 200° C
Diameter range
40-100
Qn
10-60
Temperature Range - Hot ēC
spacer
Horizontal
spacer
Mechanical
spacer
Nominal pressure PN
16, 40 spacer
Pulse
spacer
* PN 16: 180 oC<br> PN 40: 200oC
 
 
FUE 380 Flow Sensor
Diameter range
100-400
Qn
180-2500
Metrological class
spacer
Temperature Range - Hot ēC
200 spacer
Any position
spacer
Interface 0 / 4 .. 20 mA
spacer
Ultrasonic
spacer
Nominal pressure PN
16/25/40 spacer
Pulse
spacer

 
Jump to other product ranges here


1) 5 to 130 for the flow sensor
2) 10 to 130 for the flow sensor
3) 10 to 90 for the flow sensor
4) 15 to 110 for the flow sensor